In warm climates zones 1 through 4 low density open cell spray foam insulation is the typical choice since it is vapor permeable and will allow drying of the exterior sheathing and roof framing if they happen to get wet via diffusion into the interior of the building.
Insulation under roof sheathing.
The problem arises with moisture.
Look for water stains on the roof sheathing or damp or moldy spots on attic joists and existing insulation as a clue to where leaks might be.
Water is insulation s enemy.
There have been isolated moisture related incidents that raise potential concerns about the overall hygrothermal performance of these systems.
It will help you to eliminate problems that may come when the house becomes extremely cold in the winter and terribly hot in the summer.
Avoids nails or screws which could penetrate the metal roof and cause leaks.
In order to add moisture barrier under metal roof you can spray the undersides of the roof by using a thick layer of polyurethane spray foam.
T he problem with the insulation against the sheathing expands.
It hits the osb roof sheathing and keeps going through the foam into the attic air.
Use rigid foam insulation to cover wider spans of roof sheathing between joists.
At night it goes back through the foam to the osb.
There are lots of different ways to insulate this type of roof but one of the best methods calls for the installation of rigid foam insulation above the roof sheathing.
Insulation is applied in direct contact with the underside of the structural roof sheathing.
The attic or rafter assembly meets one of the following conditions regarding the air permeability of the insulation directly under the structural roof sheathing.
If there is a roof leak the insulation will be damaged by the water leaving you with less insulating value.
Insulated roof assemblies can be vented or unvented.
Unvented roof strategies with open cell and closed cell spray polyurethane foam insulation sprayed to the underside of roof sheathing have been used since the mid 1990 s to provide durable and efficient building enclosures.
Cut each sheet to the desired size using a utility knife then fasten it in place using staples or adhesive.
There are at least two good reasons why this approach makes more sense than installing the insulation under the roof sheathing.
The moisture is held in place by the insulation which allows for damage to the framing and other building components.
In most climate zones requires a minimum r value of air impermeable insulation on or under the roof deck.
One possible failure mode is that open cell foam.
Box out light fixtures.
How to retrofit a roof to a high performance roof with insulating sheathing above the roof deck plus cavity insulation in roof framing remove existing roofing and non adhered roof underlayment.
The next day even more moisture is driven inward.